Reference Information

Comment:  This is a copy without changes, of an article of good information and explanation, a British car enthusiast, archived on the SW-EM Site because the last time I clicked on it as an external link, it was lo longer there...I'm glad I saved it, as now, I have made it a permanent part of the SW-EM Site!  I have had no contact with Mr. Engel, but I thank him for writing it for the vintage car community...I know good info when I see it!  Ron 

---------------------------

Automotive Electrical Fuses -- British  Vs  American    by Mr. Tim Engel’

 

British and American standards for rating electrical fuses are different.   Both provide an “Amp Rating” for very similar looking fuses,  but the two ratings mean very different things.   The US system rates the fuse based on the continuous load it can handle for a specified period of time w/o blowing,  whilst the British system expresses the load at which the fuse will immediately blow.

 

That’s a significant difference!   As an example,  the 35 Amp fuse called out for many 1950’s/ 60’s/ 70’s  vintage Britcars  (Lotus Elan & Europa for sure)  is roughly equivalent to a US-spec  BUSS  AGC 17 Amp fuse.   Install a US 35 Amp fuse into your LBC fuse box and the wiring harness will melt down before the fuse blows.

 

DO NOT use a USA rated 35 amp fuse in your vintage British car!  [That includes the P1800! Ron]

 

The complete rating for the specified 35 amp Lucas fuse is…

“17 AMPS CONTINUOUS / 35 AMP SURGE”

Early British fuses were simply marked with the quick-blow rating,  but later fuses are given two ratings in an effort to minimize the confusion.   For instance,  the 35 Amp fuse is often marked as  “17 continuous/ 35 blow”,  or simply  17/35.   In that case,  use the lower “continuous” rating as the one to which you try to match an American  BUSS  fuse rating.   Or, better yet,  proper British fuses are available from your favorite independent Britcar / Lotus parts dealer.   Purchase a supply and keep them in your Lotus' glove box.

 

The comparison/ substitution looks something like this...

 

British Lucas Fuse                     ~  American  BUSS  Fuse

Fast Blow      Dual Rating   ~  Continuous (AGC)         Alternate Opinion (SFE ?)

50 amp         25/50 amp     ~  25 amp                          25 amp  SFE

35 amp         17/35 amp     ~  17 amp                         20 amp  SFE

30 amp         15/30 amp     ~  15 amp                          15 amp  SFE (too short ?)

25 amp         12/25 amp     ~  12 amp                          15 amp  SFE (too short ?)

20 amp         10/20 amp     ~  10 amp

15 amp        7.5/15 amp     ~    8 amp

10 amp         5 /10 amp    ~    5 amp

  5 amp        2.5 / 5 amp     ~    _____                            3 amp

  2 amp           1 / 2 amp    ~    1 amp

 

Unfortunately,  there’s no extra data marked on either the fuse body or on the package to tip-off the user that the ratings are different.   It’s very important that USA owners of British cars be aware of the issue and make wise choices when using USA  fuses in them.   The best choice is to make the effort to source proper British fuses for your LBC.   In an emergency,  the loose Rule of Thumb is to use a USA  BUSS  fuse with an Amp rating equal to no more than one half of the British Lucas fuse rating.


 

USA  BUSS  fuse terms:

 

SFE  fuses are "automotive"  and rated to interrupt only 32 volts.   Their length depends on their current rating,  ranging from 5/8" for a  SFE-4,  to 1-7/16" for a  SFE-30  (lower amperage = shorter  and  higher amperage = longer).   So,  size-wize,  sometimes higher amp rating SFE fuse will work in place of an  "AGC"  or an  "AGA"…  or a Lucas fuse.   Regardless of physical size,  an SFE will always blow more quickly than a current  AG__  (or older  __AG)  that has a similar Amp rating.

 

AGC  fuses are  “General Purpose”.   They are always  1/4" Dia  X  1-1/4" long.   They’re available in 250V ratings to 10 amps,  and up to 32V ratings to 30 amps.   AGC fuses are approximately the same length as British fuses,  and will fit in the Lucas fuse holder.   An AGC-20 is the same length as an SFE-20…  they are pretty much interchangeable.

 

Both AGC and SFE are "fast acting",  but according to  BUSS  charts,  the SFE is faster.   An AGC-20 is rated to carry 27 amps for up to 60 minutes,  while an SFE-20 will blow in under 2 minutes.   However,  the 60 minutes is given as a maximum,  while the 2 minutes is apparently typical,  so that may not be an accurate comparison.   Without getting too lost in the details,  the basic idea is that an SFE will blow faster than an AGC,  and will better protect your LBC’s vintage wiring.

 

If you are going to use  BUSS  fuses in your LBC,  then when availability and length permits,  use SFE  fuses as your first choice.   When you must use AGC fuses,  shop for the 32 volt rated versions first,  but the 250 volt AGC fuses will  “work”.   SFE fuses in lower Amp ratings will be shorter than the Lucas fuses and may not fit the Lucas fuse box properly,  so use common sense.

 

Currently  BUSS  AG fuses are available in different lengths,  denoted as AGA,  AGB  and  AGC.   They are all available in the same voltage and current ratings,  the difference being in the lengths.   AGA is the shortest,  and lengths become longer as they progress from A through C.

 

Previously,  the AG fuses were differentiated on a number scale,  1AG,  2AG  and  3AG.

The older "3AG"  fuses are the same as the modern, common  "AGC"  fuses.

Similarly:       1AG  =  AGA           and  2AG  =  AGB

I don't believe stores or catalogs list  "3AG"  or  "1AG"  fuses anymore;  they just list the current designation  "AGC"  or  "AGA"  now.

 

USA fuse styles  (The difference between them is their length)

Current  – –  OLD  designation (no longer sold)

AGA  – – – –  1AG

AGB  – – – –  2AG

AGC  – – – –  3AG  (1/4" Dia x 1-1/4",  fit Lucas fuse holder)

SFE  – – – –  

 

 

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*

 

B A C K ! . . .to Tech Articles Index Page